ECMO Clinical Management

Clinical management of ECMO — VV and VA configurations, weaning, anticoagulation, bleeding, infection, cannulation and MDT team support for ECMO centres in Australia and New Zealand.

Weaning from ECMO

Anticoagulation & Circuit Integrity

Complications & Organ Support

Adjunct Therapies & Rehabilitation

MDT, Team & Governance

Lifemotion ECMO — Exclusive ANZ Distribution by OHM Healthcare

OHM Healthcare supports ECMO centres across Australia and New Zealand with equipment, clinical training and biomedical engineering services.

Clinical Applications
OHM Healthcare is the exclusive distributor for Lifemotion ECMO across Australia and New Zealand. Learn more about OHM Healthcare click here.
ECMO & ECLS technology for Australia & New Zealand

One ECMO platform. Every stage of the journey.

One circuit that stays with the patient — from retrieval to the ICU — without breaking or re-priming. The Lifemotion ECMO platform brings the console, centrifugal pump, membrane oxygenator and integrated circuit together as one extracorporeal life support (ECLS) system — ARTG-listed in Australia and supported locally by OHM Healthcare’s Clinical Engineering team across Australia and New Zealand.

4 ARTG entries — Australia Exclusive ANZ distribution CE Mark (MDR) WAND-notified — New Zealand

Complete System → Portable Console → Pump Driver + Battery — the same circuit, reconfigured at every stage of care.

4ARTG entries for the Lifemotion ECMO system (Australia)
4,500+Global ECMO cases supported by the Lifemotion platform
CE MarkEU MDR certified design
3 layersOf pump redundancy built into every system
AllAustralian state and territory health services already supported by OHM Healthcare
2022Founded and operated by Clinical Engineers
ISO 9001Focused on quality, compliance and excellence
AS3551Lifecycle Management Expertise: in critical care and biomedical devices
Regional Partnership

Global ECMO engineering. Local clinical and biomedical support.

Lifemotion builds its ECMO platform around three stated priorities: safety, portability and integrated real-time monitoring. OHM Healthcare is the exclusive distribution and support partner bringing the Lifemotion ECMO system to NSW Health, QLD Health and other state and territory health services, retrieval services and Clinical Engineering teams across Australia and New Zealand.

This site translates Lifemotion's product documentation into a regionally relevant resource — covering the platform itself, local regulatory status, and the implementation and service support OHM Healthcare provides on the ground.

Why this partnership A significant share of ANZ’s ECMO installed base is approaching its natural replacement cycle. Lifemotion is dedicated to ECMO — focused on keeping the platform at the forefront of the technology — while OHM Healthcare brings an expert team of Clinical Engineers who already support critical care equipment across major Australian state and territory health services. Through this partnership, ANZ hospitals gain continually advancing technology with local support across the entire product lifecycle — education, service and regulatory — so clinicians can focus on what matters most: delivering the best possible patient care.

Lifemotion

Manufacturer of the Lifemotion ECMO system. Lifemotion S.r.l. (Mirandola, Italy) is Lifemotion's European service and regulatory contact; per current product documentation, the system is manufactured by Lifemotion Medical Technology Co., Ltd. (Shenzhen, China).

OHM Healthcare

ISO 9001:2015 certified biomedical distributor and service provider, founded in 2022, and an authorised ANZ distributor of critical care ventilators. Now extending its Clinical Engineering capability into ECMO.

Products

One coordinated ECMO platform, not a single component

The Lifemotion platform brings together a console, a centrifugal pump, a membrane oxygenator and an integrated circuit, all built around the same continuous circuit architecture. Specifications below are drawn from Lifemotion's published product documentation and are subject to the locally approved Instructions for Use.

Lifemotion Console
LM-ECMO-1000

Lifemotion ECMO Console

Touchscreen interface with a real-time startup checklist and a five-step guided priming sequence. Continuous monitoring of three pressure points (with differential pressure calculated across the oxygenator), flow and bubble detection, two temperature points, non-invasive oxygen saturation, hematocrit and hemoglobin. Dual internal battery packs, each stated by the manufacturer to provide up to approximately 120 minutes of runtime depending on configuration. HL7-based connectivity to hospital information systems via standard Ethernet (RJ45).

  • Dimensions 380 × 300 × 380 mm
  • Weight (console only) ~11 kg
  • Pump speed range 0–6,500 rpm
  • ARTG entry 528964
Lifemotion Disposable Membrane Oxygenator
LM-BGEA-1000

Disposable Membrane Oxygenator

A PMP (polymethylpentene) hollow-fibre membrane for gas transfer, paired with a PET heat exchanger for temperature management. Blood-contacting surfaces carry a phosphorylcholine (PC) coating, a biomimetic surface technology intended to support hemocompatibility during extracorporeal circulation.

  • Blood flow range 0.5–7.0 L/min
  • Sweep gas flow 0–14 L/min
  • Priming volume 300 mL
  • Membrane area 2.0 m²
  • Indicated use up to 14 days*
  • ARTG entry 528771
Lifemotion Disposable Centrifugal Pump Head
LM-PH-1000

Disposable Centrifugal Pump Head

A magnetically driven centrifugal impeller on a single-point pivot, generating controlled radial blood propulsion. Compact chamber with a low, 17 mL priming volume, and the same phosphorylcholine-coated blood-contact surfaces as the oxygenator and ECMO sets.

  • Flow rate up to 7.0 L/min
  • Drive speed up to 6,500 rpm
  • Priming volume 17 mL
  • Indicated use up to 14 days*
  • ARTG entry 528772
Disposable ECMO SetReferenceTube lengthIntegrated sensing
Standard ConfigurationLM-TPS-10002.2 mPressure, temperature, flow & bubble detection
Extended ConfigurationLM-TPS-1000L2.65 mPressure, temperature, flow & bubble detection
Advanced Monitoring ConfigurationLM-TPS-1500L2.65 mAdds hematocrit, hemoglobin & oxygen saturation

Each set is a pre-assembled sterile circuit integrating the centrifugal pump head, oxygenator and complete tubing for bedside deployment, indicated for use up to 14 days.* ARTG entry 528773.

T
LMF-10-001

Lifemotion Trolley

Steel-framed, height-adjustable platform supporting the console and disposables at the bedside, with integrated fixtures for a spare pump drive motor, sensor cabling, IV poles and heater-cooler mounting.

C
LMF-13-002

Carbon Fibre Support Frame

A lightweight carbon fibre frame that turns the pump driver, battery module and disposables into a compact, self-contained mobile core configuration for standalone operation away from the trolley.

Lifemotion ECMO system mounted on a transport stretcher
LMF-13-004

Transport-Ready Backpack

A dedicated backpack for carrying system components between sites, developed alongside a carrier and mounting system for stretchers, ambulances and aircraft, engineered in collaboration with Starmed GmbH.

Read before you rely on any spec All performance figures on this page are manufacturer-published specifications. Locally approved labelling and the current Instructions for Use always take precedence — confirm against these before quoting a figure in a tender or clinical setting. *Indicated duration of use is stated in accordance with EU MDR registration; availability and approved indications may vary by country.
Continuity Without Compromise

Three layers of pump redundancy

An integrated redundancy architecture is designed to preserve ECMO support through automatic backup and direct manual control, whenever needed.

1

Main pump drive motor

Delivers primary centrifugal pump control with integrated safety monitoring and real-time system feedback, supporting stable, continuous extracorporeal circulation.

2

Backup pump drive motor

A dedicated, independently powered backup motor enables continued ECMO support in critical situations, with independent control via the main unit or the battery-powered driver.

3

Manual hand crank

A fully mechanical final layer of redundancy, ensuring pump operation can continue independent of electrical supply.

Applications

Built around continuity of care across settings

Lifemotion's stated design focus includes portability and transport-oriented workflow, relevant to the geographically dispersed nature of ECMO retrieval across Australia and New Zealand.

Lifemotion ECMO Complete System — full performance platform on trolley

ICU care

Continuous extracorporeal life support with centralised, real-time visibility of flow, pressure, temperature, oxygen saturation, hematocrit and hemoglobin, integrated into standard ICU monitoring workflows.

Lifemotion Transport-Ready Backpack for rapid deployment Lifemotion Mobile Core Module — compact standalone setup

Emergency & rapid deployment

A real-time startup checklist and five-step guided priming sequence support time-critical initiation, subject to local protocols and staff training.

Lifemotion ECMO system mounted on a transport stretcher Lifemotion Console standalone unit for transport

Retrieval & transport

Portable, dual-battery configurations and a stretcher/ambulance/aircraft carrier system, developed with Starmed GmbH, intended for inter-hospital and intra-hospital transfers within approved transport configurations.

Surface Technology

Phosphorylcholine coating on every blood-contacting surface

The oxygenator, centrifugal pump head and ECMO sets all carry a phosphorylcholine (PC) coating — a biomimetic surface technology designed to replicate the outer structure of cell membranes, intended to support a more biologically familiar interface for blood contact and reduce protein and cell adhesion.

Phosphorylcholine coatings in extracorporeal circuits have been described in peer-reviewed literature, including De Somer F, Francois K, Van Oeveren W, et al., Eur J Cardiothorac Surg, 2000. Clinical relevance of coating technology should be assessed against the current Instructions for Use and local evidence requirements.

✓

Reduced thrombogenic potential

Intended to help limit clot formation within the extracorporeal circuit.

✓

Supports hemocompatibility

Intended to promote a more physiological interaction between blood and device surfaces.

✓

Reduced inflammatory response

Intended to minimise activation of inflammatory pathways during prolonged extracorporeal support.

✓

DEHP-free circuit

Per Lifemotion, all blood-contacting internal surfaces of the ECMO set are free of DEHP.

Regulatory & Compliance

Australian Register of Therapeutic Goods (ARTG) status

The Lifemotion ECMO system holds four current ARTG entries, sponsored by SASS Biomedical Engineering Services t/a OHM Healthcare Engineering Services. Inclusion on the ARTG means the listed products may lawfully be supplied in Australia, subject to the conditions on each entry.

ARTG No.TGA product listingSponsor's referenceDate of entry
528964Cardiopulmonary bypass system centrifugal pump drive unitLifemotion Console15/07/2026
528771Oxygenator, extracorporeal membraneLifemotion Disposable Membrane Oxygenator9/07/2026
528772Cardiopulmonary bypass system centrifugal pumpDisposable Centrifugal Pump Head9/07/2026
528773Extracorporeal cardiopulmonary support system circuitLifemotion Disposable ECMO Set9/07/2026
CE Mark (EU MDR) ISP — Chile SAHPRA — South Africa MDD — Hong Kong MHRA — United Kingdom ARTG — Australia
✓

Clinical Engineering

OHM Healthcare's Clinical Engineers provide installation support, commissioning and first-line troubleshooting, extending the same service model already used for ventilators and other critical care equipment.

✓

Quality & compliance

ISO 9001:2015 certified and AS3551-compliant (the Australian standard for medical equipment testing), applied consistently across OHM's biomedical service portfolio.

✓

Existing health service network

OHM Healthcare already supports health services including NSW, QLD, ACT, TAS, NT and WA Health, and paediatric hospitals such as Royal Children's Hospital and Perth Children's Hospital, through its existing critical care ventilator distribution and service business.

✓

Training & demonstration

Demonstration and wet-lab sessions are being scheduled with ECMO centres across Australia as part of the Lifemotion ECMO launch programme.

Local Support

OHM Healthcare: local implementation, not product supply alone

Introducing an ECMO platform is a multidisciplinary undertaking — clinical leadership, perfusion, ICU, Clinical Engineering, procurement and executive governance are all typically involved. OHM Healthcare's role is to support that pathway locally: coordinating implementation, providing Clinical Engineering service, and acting as the single regional point of contact for the Lifemotion ECMO system.

  • Single regional point of contact for product, technical and service enquiries
  • Local Clinical Engineering team, not an offshore service desk
  • Established relationships across major Australian health networks
  • Calls answered by a real person with direct expertise in the device, not a call centre
Frequently Asked Questions

ECMO and extracorporeal membrane oxygenation, explained

What is ECMO?

ECMO stands for extracorporeal membrane oxygenation — a form of extracorporeal life support that takes over the work of the heart and/or lungs for a patient in cardiac or respiratory failure. Blood is drawn from the body, passed through a mechanical pump and an artificial membrane oxygenator to add oxygen and remove carbon dioxide, then returned to the patient.

What does an ECMO machine consist of?

An ECMO system typically comprises a console (the control and monitoring unit), a centrifugal pump, a membrane oxygenator and a circuit of tubing connecting them to the patient. The Lifemotion ECMO system packages these as the Lifemotion Console, Disposable Centrifugal Pump Head, Disposable Membrane Oxygenator and Disposable ECMO Set.

Is the Lifemotion ECMO system approved for use in Australia?

Yes. The Lifemotion ECMO system holds four current ARTG (Australian Register of Therapeutic Goods) entries, sponsored by SASS Biomedical Engineering Services t/a OHM Healthcare Engineering Services, covering the console, centrifugal pump, membrane oxygenator and ECMO set.

Who distributes and supports Lifemotion ECMO in Australia and New Zealand?

OHM Healthcare is the exclusive Australia and New Zealand distributor for the Lifemotion ECMO system, providing local Clinical Engineering support, installation, commissioning and first-line troubleshooting.

Can the Lifemotion ECMO system be used for retrieval and transport?

Yes. The platform is designed with portable, dual-battery configurations and a stretcher/carrier system, developed with Starmed GmbH, intended for inter-hospital and intra-hospital transfers within approved transport configurations.

What is the difference between ECMO consoles on the market?

ECMO consoles vary in portability, redundancy architecture, monitoring depth and circuit configuration. The Lifemotion ECMO system is built around three layers of pump redundancy, phosphorylcholine-coated blood-contacting surfaces, and a modular design that reconfigures from a compact core module through to a complete trolley-based platform. If you're evaluating options for your service, OHM Healthcare's Clinical Engineering team can walk through a side-by-side technical comparison against your current console.

Contact

Talk to the regional Lifemotion ECMO team

For health service, technical or procurement enquiries across Australia and New Zealand.

OHM Healthcare

📍10/39 Barrie Road, Tullamarine, VIC 3043, Australia
☎03 9115 7464 — for urgent matters, please call our office
🔧Technical support: support@ohmhealthcare.com.au

Prefer a direct conversation?

NSW Health, QLD Health and other state and territory Clinical Engineering teams, clinicians and procurement contacts can request a system demonstration, technical specification pack or wet-lab session directly from the OHM Healthcare team. For urgent enquiries, please call our office directly.

Email sales Email support
Lifemotion ECMO Australia & New Zealand

Exclusively distributed and supported by OHM Healthcare.

LifemotionOHM Healthcare
Manufacturer

lifemotionmedical.com

Lifemotion S.r.l. (EU service & regulatory contact), Via di Mezzo 75/A, 41037 Mirandola (MO), Italy

Manufactured by Lifemotion Medical Technology Co., Ltd., Shenzhen, China